MDIC Rund Innendørs 4xSM G657.A1
Micro Drop Installation Cables
Standardlengde Reel in box 500m
MOQ: 500m
The Micro Drop Installation Cable Dca (MDIC-Dca) is a special Access cable with low bend radius, no waterpeak G.657.A1 fibres.
Ruggedized construction with excellent installation performance, easy strippable for fast installation. This cable solves all in-house
installation problems.
Product characteristics |
|
Cable type |
MDIC |
Fibre type |
Single mode 9/125 |
Optical fibre standard |
ITU-T G.657.A1 |
Number of fibers |
4 |
Cable metal free |
Yes |
Strip method |
Double sided Rip seam |
Strain relief |
Yes |
Type of strain relief |
FRP |
Material outer sheath |
LSZH |
Colour outer sheath |
White |
Outer sheath thickness |
1 mm |
Outer diameter approx. |
3,7 mm |
Marking |
ACE - TKF MDIC Dca 4x SM G.657.A1 (1x4) 69278 {Batch} [-CE-] DOP0052 {Year} {Length} |
Application |
|
Test procedures |
EN IEC 60794-1-2 |
Application |
Inside |
Euro fire class according to EN 13501-6 |
Dca |
Euro class smoke production according to EN 13501-6 |
s2 |
Euro class flaming droplets/particles according to EN 13501-6 |
d2 |
Euro class acidity according to EN 13501-6 |
a1 |
Mechanical specification |
|
Tensile load short term (Tm) |
150 N |
Tensile load Long Term (Tl) |
50 N |
Min. bending radius during installation |
56 mm |
Min. bending radius after installation |
37 mm |
Crush resistance acc. meth.E3A |
1300 N/dm |
Crush resistance E3A long |
1000 N/dm |
Crush load E3A long application time |
10 min |
Crush resistance E3B short term (1min) |
1300 N/dm |
Crush resistance E3B long term |
250 N/dm |
Crush load E3B long application time |
10 min |
Mandrel diameter by Crush meth. E3B |
25 mm |
Impact strength |
3 J |
Striking surface radius |
10 mm |
Torsion resistance |
1800 °/m |
Kink resistance |
30 mm |
Optical specification |
|
Category according to EN 50173 |
OS2 |
Max. attenuation @ 1310 nm |
0,4 dB/km |
Max. attenuation @ 1550 nm |
0,3 dB/km |
Bending radius fibre storage (<10 turns acc ITU rec) |
15 mm |
Environmental specification |
|
Longitudinal water blocking cable |
No |
Installation temperature |
-10/50 °C |
Transportation and storage temperature |
-30/70 °C |
Operational temperature range Ta1 - Tb1 |
-30/70 °C |
UV resistant |
Yes |
UV-protection |
ISO 4892/2 |
Other specification |
|
Halogen free (acc. EN 60754-1/2) |
Yes |
Vertical flame propagation (for single cable) |
IEC 60332-2-2 / EN 50265-2-2 |
Vertical flame spread (for bunched cables) |
IEC 60332-3-24 / EN 50266-2-4 (cat.C) |
Caloric value |
0,3 MJ/km |
Logistical specifications |
|
Unit |
meter |
Weight (kg) |
0.016 |
Default packaging |
H X 500/25 |